Thermostatic three-way valves for boiler protection, TEPLOMIX with by-pass closing function
7766
THERMOSTATIC THREE-WAY VALVES FOR BOILER PROTECTION, TEPLOMIX WITH BY-PASS CLOSURE FUNCTION (7766)

Thermostatic 3-way valve for boiler protection, TEPLOMIX with by-pass closure function.
Model with closing function of the circulation flow at ~63 ºC and reopening at ~55 ºC.
Used to protect boilers from condensation by increasing the temperature of the return flow.
Equipped with a factory-set thermostat that automatically controls the bypass without auxiliary energy.
Brass housing, in yellow (uncoated) finish, with threaded connection and 3/8 plug for drain valve.
Drain valve 1 0276 00 and pipe connection 1 6206 01 must be ordered separately.
Connection with external thread type G with flat seal in accordance with ISO 228 standard.
Maximum working temperature: 110 ºC (without steam)
Minimum working temperature: -20 ºC (water 2 ºC)
Maximum operating pressure: 16 bar
Maximum pressure drop on the pipe: 0.5 bar
  • DIMENZIJE
  • DOCUMENTATION

Name

Kvs [m3/h]

PN [bar]

Connection

Size

Article Number

Packaging

Thermostatic valve with 3 paths for boiler protection, TEPLOMIX with by-pass closure function

11.00

16

3xFE 1 1/4 G flat

DN 25

1 7766 13

1

Thermostatic valve with 3 paths for boiler protection, TEPLOMIX with constant flow by-pass

14.00

16

3xFE 1 1/2 G flat

DN 32

1 7766 14