Safety Heat Valves for Wood Boilers
2801
2801
SAFETY THERMAL VALVES FOR WOOD BOILERS (2801)
Safety thermal valve for wood boilers.
Used to protect wood boilers from overheating.
Can be used on wood boilers equipped with a cooling coil.
Body made of forged brass, in yellow (uncoated) finish, brass according to EN 12165 standard.
Special steel spring, double copper sensor in 157.5 mm x 1/2 jacket, capillary tube 1.3 m.
Connection with internal thread type G according to ISO 228 standard.
Sealing with rubber seals (EPDM).
Opening temperature: 95 ºC
Maximum working temperature for the sensor: 125 ºC
Maximum operating pressure: 10 bar
Maximum boiler thermal power: 100 kW
Discharge rate at Δp 1 bar: 1.35 m3/h
Safety thermal valve for wood boilers.
Used to protect wood boilers from overheating.
Can be used on wood boilers equipped with a cooling coil.
Body made of forged brass, in yellow (uncoated) finish, brass according to EN 12165 standard.
Special steel spring, double copper sensor in 157.5 mm x 1/2 jacket, capillary tube 1.3 m.
Connection with internal thread type G according to ISO 228 standard.
Sealing with rubber seals (EPDM).
Opening temperature: 95 ºC
Maximum working temperature for the sensor: 125 ºC
Maximum operating pressure: 10 bar
Maximum boiler thermal power: 100 kW
Discharge rate at Δp 1 bar: 1.35 m3/h
Name |
P boiler [kW] |
PN [bar] |
Connection |
Size |
Article Number |
Packaging |
Thermostatic safety valve for wood boilers |
100 |
10 |
FI-FI 3/4 |
DN 20 |
1 2801 95 |
2 |