Ball valve with a free-turning nut
1222103-1222104
1222103-1222104
The valve is most commonly used in cases where a free-turning nut is required for direct mounting on the system due to lack of space. It is often used when connecting to a drinking water distributor, during the installation of water meters, and in similar cases where space is limited. A seal is included with the valve.
| ident | EAN | DN | PN | G [in] | L [mm] | L1 [mm] | L2 [mm] | L3 [mm] | H | A | Sw | Sw1 | peckaging | |
| 1222103 | 3838963247401 | 20 | 25 | G3/4˝ | 73,2 | 9 | 11 | 65,5 | 41,8 | 55 | 30 | 31 | 25 | |
| 1222104 | 3838963247449 | 20 | 25 | G1˝ | 84 | 12 | 18 | 74,5 | 41,8 | 55 | 37 | 38 | 16 | |
Ball valves with a free-turning nut are most commonly used when installing brass distributors 15300xx (2 8530 xx), during the installation of water meters, and in similar situations where space is limited. These valves are designed for easy and quick installation, thanks to the free-turning nut. Please note that a flat seal is also included with the valve for reliable sealing.

- Declaration of conformity - SLO, ENG, DEU
Operating data:
Medium:
The purity of the water must comply with the standards ÖNORM H 5195 and VDI 2035. The use of ethylene or propylene glycol in a mixing ratio of 25–50% is permitted. EPDM seals are sensitive to lubricants containing mineral oils, which may cause damage to the seals. When using ethylene glycol products for freeze and corrosion protection, please follow the manufacturer's documentation.
- Maximum operating pressure: 25 bar
- Minimum operating temperature: -30 °C (water 0.5 °C)
- Maximum operating temperature: 150 °C (water 110 °C, without steam)
- Medium: sanitary water or water for heating systems
- Connections: internal G3/4" (1222103) and G1" (1222104) according to ISO 228
Medium:
The purity of the water must comply with the standards ÖNORM H 5195 and VDI 2035. The use of ethylene or propylene glycol in a mixing ratio of 25–50% is permitted. EPDM seals are sensitive to lubricants containing mineral oils, which may cause damage to the seals. When using ethylene glycol products for freeze and corrosion protection, please follow the manufacturer's documentation.